EM100-F User Manual
0084293
Page 72 of 93
5.13.26. PD21 Bag Rupture Blanking
The control of filling slope is disabled for ‘PD21’ milli-seconds from opening the coarse valves to
allow oscillation on the weight during the first part of the filling.
Master Sends
Slave Responds With
Meaning
PD21
P21+00200
Filling Slope Disabled for 200ms.
PD21 500
OK
Setup: Set Filling Slope Disabled for
500ms.
5.13.27. TR Trigger
This command will start the measuring cycle in the same way as the hardware trigger input.
Master Sends
Slave Responds With
Meaning
TR
OK
Request: Trigger Started.
Note: This function can be used as a soft trigger to start a filling process.