EasyManua.ls Logo

Flintec EM100-C - Page 71

Flintec EM100-C
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EM100-C User Manual
0084292
Page 71 of 81
6.2.1.2. Manufacturer Segment
6.2.1.2.1. Save Parameters
Index
Sub
Index
Name
Type
Attribute
Default
Value
Description
2004
0
1
2
3
4
5
No. of Entries.
Dummy.
Save Calibration
Save General.
Save Dosing.
Save Set-Point.
UI8
UI8
UI8
UI8
UI8
UI8
ro
wo
wo
wo
wo
wo
5
-
0.
0.
0.
0.
No. of Entries.
Not Used.
Save Calibration Settings (TAC).
Save General Settings.
Save Dosing Settings.
Save Set-Point Settings.
6.2.1.2.2. Gateway Parameters
Index
Sub
Index
Name
Type
Attribute
Default
Value
Description
2006
0
1
2
3
4
No. of Entries.
Dummy.
Set Factory Default.
Command Byte1.
Command Byte2.
UI8
UI8
UI8
UI8
UI8
ro
wo
wo
wo
wo
4.
-
0.
0.
0.
No. System Entries.
Not Used.
Set Factory Defaults (TAC).
See RPDO1.
See RPDO2.

Table of Contents