5500A-SC600 Option
SC600 Option Specifications
8
8-9
8-6. Time Marker Specifications
Table 8-4. Time Marker Specifications
Time Maker into 50 5 s to 50 ms 20 ms to 100 ns 50 ns to 20 ns 10 ns 5 ns to 2 ns
1-Year Absolute
Uncertainty at Cardinal
Points, tcal ±5 ° C [3]
±(25 + t *1000)
ppm [1]
± 2.5 ppm ± 2.5 ppm ± 2.5 ppm ± 2.5 ppm
Wave Shape spike or
square
spike, square, or
20%-pulse
spike or
square
square or
sine
sine
Typical Output Level > 1 V p-p [2] > 1 V p-p [2] > 1 V p-p [2] > 1 V p-p [2] > 1 V p-p
Typical Jitter (rms) <10 ppm < 1 ppm < 1 ppm < 1 ppm < 1 ppm
Sequence (cardinal points) 5-2-1 from 5 s to 2 ns (e.g., 500 ms, 200 ms, 100 ms)
Adjustment Range At least ± 10% around each cardinal point.
Amplitude Resolution 4 digits
[1] t is the time in seconds. Examples: At 5 s the uncertainty is 5,025 ppm; At 50 ms the uncertainty is 75
ppm.
[2] Typical rise time of square wave and 20%-pulse (20% duty cycle pulse) is < 1.5 ns.
[3] Away from the cardinal points, add ±50 ppm to uncertainty.
8-7. Wave Generator Specifications
Table 8-5. Wave Generator Specifications
Wave Generator Characteristics
Square Wave, Sine Wave, and Triangle Wave
into 50 or 1 M
Amplitude
Range into 1 M: 1.8 mV to 55 V p-p
into 50 : 1.8 mV to 2.5 V p-p
1-Year Absolute Uncertainty, tcal ± 5 °C,
10 Hz to 10 kHz
± (3% of p-p output + 100 µV)
Sequence 1-2-5 (e.g., 10 mV, 20 mV, 50 mV)
Typical DC Offset Range 0 to ± (40% of p-p amplitude) [1]
Frequency
Range 10 Hz to 100 kHz
Resolution 4 or 5 digits depending upon frequency
1-Year Absolute Uncertainty, tcal ± 5 °C ± (25 ppm + 15 mHz)
[1]The DC offset plus the wave signal must not exceed 30 V rms.