EasyManua.ls Logo

Fluke 5500A - Leveled Sinewave Verification: Amplitude; Leveled Sinewave Verification: Frequency

Fluke 5500A
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5500A-SC600 Option
Verification Tables
8
8-45
8-62. Leveled Sinewave Verification: Amplitude
Table 8-21. Leveled Sinewave Verification: Amplitude
Nominal
Value (V p-p)
Frequency Measured
Value (V p-p)
Deviation
(V p-p)
1-Year Spec.
(V p-p)
0.005 50 kHz 0.0004
0.0075 50 kHz 0.00045
0.0099 50 kHz 0.000498
0.01 50 kHz 0.0005
0.025 50 kHz 0.0008
0.039 50 kHz 0.00108
0.04 50 kHz 0.0011
0.07 50 kHz 0.0017
0.099 50 kHz 0.00228
0.1 50 kHz 0.0023
0.25 50 kHz 0.0053
0.399 50 kHz 0.00828
0.4 50 kHz 0.0083
0.8 50 kHz 0.0163
1.2 50 kHz 0.0243
1.3 50 kHz 0.0263
3.4 50 kHz 0.0683
5.5 50 kHz 0.1103
8-63. Leveled Sinewave Verification: Frequency
Table 8-22. Leveled Sinewave Verification: Frequency
Nominal
Value (V p-p)
Frequency Measured
Value (Hz)
Deviation
(Hz)
1-Year Spec.
(Hz)
5.5 50 kHz 0.125
5.5 500 kHz 1.25
5.5 5 MHz 12.5
5.5 50 MHz 125
5.5 500 MHz 1250