Fluke 5700A Series II User Manual

Fluke 5700A Series II
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Contents (continued)
iii
4-27. DC Current Output ........................................................................... 4-27
4-28. AC Current Output ........................................................................... 4-28
4-29. Resistance Output............................................................................. 4-30
4-30. Wideband AC Voltage Output (Option 5700A-03) ......................... 4-32
4-31. Variable Phase Output...................................................................... 4-34
4-32. Phase Locking to an External Signal .................................................... 4-35
4-33. Using an Auxiliary Amplifier ............................................................... 4-36
4-34. 5725A Amplifier Output .................................................................. 4-37
4-35. Checking the Calibrator’s Uncertainty Specification ........................... 4-38
4-36. Error Mode Operation........................................................................... 4-38
4-37. Error Mode Overview....................................................................... 4-39
4-38. Entering Error Mode .................................................................... 4-39
4-39. Exiting Error Mode ...................................................................... 4-39
4-40. Using Error Mode ........................................................................ 4-40
4-41. Reading the UUT Error: AC and DC Voltage and Current Output.. 4-40
4-42. Reading the UUT Error: Resistance Output ..................................... 4-41
4-43. Introduction to Offset, Scale, and Linearity Errors............................... 4-42
4-44. Offset Error....................................................................................... 4-42
4-45. Scale Error........................................................................................ 4-43
4-46. Linearity Error.................................................................................. 4-44
4-47. Combining the Error Types.............................................................. 4-44
4-48. Programming an Offset......................................................................... 4-45
4-49. Programming a Scale Factor................................................................. 4-46
4-50. Linearity Checking Using Offset and Scale.......................................... 4-47
4-51. Setting Output Limits............................................................................ 4-50
4-52. Setting Voltage and Current Limits.................................................. 4-50
4-53. Sample Applications ............................................................................. 4-51
4-54. Calibrating Fluke 70 Series Multimeter ........................................... 4-51
4-55. Cables........................................................................................... 4-52
4-56. Guarding....................................................................................... 4-52
4-57. Sensing ......................................................................................... 4-52
4-58. Testing the Meter ......................................................................... 4-53
4-59. Calibrating the Meter ................................................................... 4-54
4-60. Calibrating a Fluke Model 8840A Series Digital Multimeter .......... 4-56
4-61. Cables........................................................................................... 4-56
4-62. Guarding....................................................................................... 4-56
4-63. Sensing ......................................................................................... 4-58
4-64. Basic Calibration Procedure......................................................... 4-58
4-65. Calibration Setup Procedure ........................................................ 4-58
4-66. A/D Calibration............................................................................ 4-59
4-67. Offset and Gain Calibration ......................................................... 4-60
4-68. High Frequency AC Calibration .................................................. 4-62
4-69. Performing A Wideband Flatness Test............................................. 4-63
5 Remote Operation ............................................................................... 5-1
5-1. Introduction........................................................................................... 5-3
5-2. Using the IEEE-488 Port for Remote Control ...................................... 5-4
5-3. IEEE-488 Bus Restrictions............................................................... 5-4
5-4. Bus Setup Procedure......................................................................... 5-4
5-5. Using the RS-232C Port for Remote Control ....................................... 5-5
5-6. Serial Remote Control Setup Procedure........................................... 5-6
5-7. Exceptions for Serial Remote Control.............................................. 5-7
5-8. Command Syntax Information.............................................................. 5-7
5-9. Parameter Syntax Rules.................................................................... 5-8

Table of Contents

Other manuals for Fluke 5700A Series II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 5700A Series II and is the answer not in the manual?

Fluke 5700A Series II Specifications

General IconGeneral
TypeMultifunction Calibrator
Operating Temperature0 °C to 50 °C
Storage Temperature-20 °C to 70 °C
Voltage Range0 to 1100 V
DC Voltage Range10 μV to 1100 V
Frequency Range1 MHz
Humiditynon-condensing
Power Requirements100 V to 240 V