DSX-600 CableAnalyzer
Technical Reference Handbook
98
Turn off the AC wire map test if the PoE device supplies power
on pairs 4,5 and 7,8. In those devices, the inputs and outputs
are fully isolated on those pairs. To do tests through those
devices, use a PoE test limit such as POE 2-Pair Cat 6 Perm.
Link. The PoE limits are in the Application group on the TEST
LIMIT screen.
How to Do an Autotest Through a PoE Device
1 Turn on the AC Wire Map test.
2 Make sure that the other settings shown on the home screen
are correct.
3 Connect to the cabling as shown in Figure 47 for a permanent
link or Figure 48 for a channel
4 Make sure that the PoE device is turned off.
5 Do an Autotest as described on page 87.