Chapter 12: Specifications
Internal Memory for Test Results
213
Internal Memory for Test Results
You can save approximately 12,700 Cat 6A Autotest results, with
plot data included, in the tester’s internal memory.
The capacity available for test results depends on the space used
by the software and custom test limits in the tester.
USB Flash Drive
You can upload test results to a USB flash drive to make more
internal memory available.
Note
The tester reads only USB drives that use the FAT
format.
Serial Interfaces
USB host interface with a type A USB port: Lets you save test
results on a USB flash drive and connect a Wi-Fi adapter for
access to Fluke Networks cloud services such as LinkWare
Live.
USB interface with a Micro-AB USB port: Lets you connect to a
PC to upload test results and update the tester’s software.
RJ45 Connector on the Main Unit
Lets you connect to a network for access to Fluke Networks cloud
services such as LinkWare
Live.
Headset Jack
Connects to a stereo headset, 32  with microphone, 22  and
3.5 mm plug. See Figure 79.