183
Chapter 10: Custom Media and Test
Limits
Make a Custom Copper Cable Type
If a twisted pair or coaxial cable installation has a cable type that
is not in the list of types in the tester, you can make a custom
cable type for the job. A custom cable type has these settings:
Custom cable name
Standard cable type used for default values
NVP (nominal velocity of propagation)
You can make up to 20 custom cable types. The tester keeps
custom cable types with the other cable types in the main
DSX-600 unit. The names of custom cable types have an asterisk
(*) at the start and end.
Use the values specified by the cable manufacturer to make the
custom cable type.
To make a custom cable type
1 On the home screen, tap the test setup panel.
2 On the CHANGE TEST screen, tap a copper test, then tap EDIT.
Note
You must select a test before you make a custom
cable type, but you can use the cable type in any
test that supports the category of the cable.
3 On the TEST SETUP screen, tap Cable Type, tap MORE, tap
Custom, then tap MANAGE.
4 On the MANAGE CUSTOM screen, tap the Create panel.
-continued-