121
Chapter 6: Diagnose Copper Test
Failures
Causes of Twisted Pair Test Failures
Table 7. Causes of Twisted Pair Test Failures
Wire Map test fails
Open
Wires connected to wrong pins at connector or punchdown blocks
Bad connection
Damaged connector or cable
Wrong application for the cable or the wrong outlet configuration is
selected
Short
Damaged connector or cable
Conductive material stuck between pins at connector
Incorrect termination at a connector
Wrong application for the cable
Split pair, reversed pair, or crossed wires
Wires connected to wrong pins at connector or punchdown block
Note
The HDTDX analyzer can help you locate split pairs.
See page 127.
Crossed pairs
Wires connected to wrong pins at connector or punchdown block
Mix of T568A and T568B wiring standards (1,2 and 3,6 crossed)
Crossover cables used where not needed (1,2 and 3,6 crossed)
Note
To do the wire map test continuously while you look
for a fault, tap SCAN ON on the WIRE MAP FAIL
screen, or tap TOOLS
> Single Tests > Wire Map.