Propagation Delay
Delay Skew
DC Loop Resistance
HDTDX Analyzer Specifications for Cables <100 m (328 ft)
Twisted Pair Cabling
Parameter Without Remote With Remote
Range 4000 ns 750 ns
Resolution 1 ns 1 ns
Accuracy (2 ns + 2 %); 0 ns to 750 ns
(2 ns + 4 %); 750 ns to 4000 ns
(2 ns + 2 %)
Parameter Twisted Pair Cabling
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy 10 ns
Parameter Twisted Pair Cabling
Range 0 to 540
Resolution 0.1
Accuracy (1 + 1 %)
Overload
Recovery Time
Less than 10 minutes to rated accuracy following an
overvoltage. Referencing is required after repeated or
prolonged overvoltage.
Parameter Twisted Pair Cabling
Distance accuracy (0.3 m (1 ft) + 2 % distance)