DSX-600 CableAnalyzer
Technical Reference Handbook
208
Length of Twisted Pair Cabling
Note
Length specifications do not include the uncertainty of the
cable’s NVP value.
Directivity 1to 300MHz:
27 - 7log(f/100),
30 dB maximum
300 to 500 MHz:
23.7 dB
(applicable when
IL > 3 dB)
1to 300MHz:
25 - 7 log(f/100), 30 dB maximum
300 to 500 MHz: 21.7 dB
(applicable when IL > 3 dB)
Source Match 20 dB (applicable when IL > 3dB)
Return loss of
Termination
1to 250MHz:
20 - 15log(f/100),
25 dB maximum
250 to 500 MHz:
14 dB
(applicable when
IL > 3 dB)
1to 250MHz:
18 - 15 log(f/100), 25 dB maximum
250 to 500 MHz: 12 dB
(applicable when IL > 3 dB)
Parameter
Twisted Pair Cabling
Without Remote With Remote
Range 800 m (2600 ft) 150 m (490 ft)
Resolution 0.1 m or 1 ft 0.1 m or 1 ft
Accuracy (0.3 m + 2 %); 0 m to 150 m
(0.3 m + 4 %); 150 m to 800 m
(0.3 m + 2 %)
DSX-600 Level V Accuracy Performance Parameters
per IEC Guidelines (continued)
Parameter
Baseline Field
Tester
Field Tester with
Level V Permanent
Link Adapter
Field Tester with
Level V Channel
Adapter