EasyManua.ls Logo

FORST ST6P - Charging the Battery

Default Icon
121 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Redwood Global Ltd - ST6P
Operator and Maintenance Manual
Chapter 5: Maintenance
5.16.4 CHARGING THE BATTERY
If the woodchipper has a flat battery, charge the battery.
NOTICE
When charging the battery, take the following into consideration:
Ensure good ventilation
Use suitable direct current mains chargers only
The charging current should be 10% of the battery Ah power rating
Use a charger with a constant charging voltage of 14.4V
If the acid temperature rises above 38°C, stop charging
To charge the battery:
1. Replace the battery as described in "
Replacing the battery
" on the previous
page.
2. Remove the battery from the woodchipper.
3. Connect the battery's positive terminal to the charger output positive.
4. Connect the battery's negative terminal to the charger output negative.
5. Switch on the charger.
The battery is fully charged when the charging voltage or acid specific gravity
has stopped rising for two hours.
6. When charging is complete, switch off the charger, then disconnect the battery.
7. Install the battery.
12-00-001 v4.0 100