141
EN
PushPull hosepack
General X Duty cycle in %
I
max
Max. welding current in A
Voltage measurement (V-Peak):
- for mechanically-driven welding torches: 141 V
The product conforms to the requirements of the IEC 60974-7 standard.
MHP 400i RD / G MHP 400i RD / G / PAP
X / I
max
(10 min/40 °C)
M21 (EN 439)
40% D.C.* 400
60% D.C.* 320
100% D.C.* 260
40% D.C.* 400
60% D.C.* 320
100% D.C.* 260
X / I
max
(10 min/40 °C)
C1 (EN 439)
60% D.C.* 400
100% D.C.* 320
60% D.C.* 400
100% D.C.* 320
[mm (in.)] 0.8-1.6 (0.030-0.062) 0.8-1.6 (0.030-0.062)
[m (ft.)] 0.935 (3.07) / 1.085 (3.56)
/1.235 (4.05) / 1.435 (4.71)
/ 1.735 (5.69) /
2.235 (7.33) / 2.735 (8.97)
/ 3.235 (10.60) /
3.735 (12.25)
0.915 (3.00) / 0.945 (3.1) / 1.025 (3.36) / 1.045 (3.43)
1.075 (3.35) / 1.105 (3.63) / 1.115 (3.66) / 1.135 (3.72)
/ 1.165 (3.82) / 1.175 (3.86) / 1.185 (3.89) / 1.205 (3.95)
/ 1.295 (4.25) / 1.335 (4.38) / 1.355 (4.45) / 1.385 (4.54)
/ 1.415 (4.64) / 1.495 (4.9) / 2.265 (7.43)
* D.C. = Duty cycle
Ø
MHP 500i RD / W MHP 500i RD / W / PAP
X / I
max
(10 min/40 °C)
M21 (EN 439)
100% D.C.* 500 100% D.C.* 500
X / I
max
(10 min/40 °C)
C1 (EN 439)
100% D.C.* 500 100% D.C.* 500
[mm (in.)] 0.8-1.6 (0.032 - 0.063) 0.8-1.6 (0.032 - 0.063)
P
min
**)
[m] ([W])
[ft.] ([W])
0.935 (550) / 1.085 (600) /
1.235 (650) / 1.435 (700) /
1.735 (800) / 2.235 (950) /
2.735 (800) / 3.235 (900) /
3.735 (1000)
3.07 (550) / 3.56 (600) /
4.05 (650) / 4.71 (700) /
5.69 (800) / 7.33 (950) /
8.97 (800) / 10,60 (900) /
12.25 (1000)
0.915 (550) / 0.945 (550) / 1.025 (550) / 1.045 (550) /
1.075 (600) / 1.105 (600) / 1.115 (600) / 1.135 (600) /
1.165 (600) / 1.175 (600) / 1.185 (600) / 1.205 (600) /
1.295 (650) / 1.335 (650) / 1.355 (650) / 1.385 (650) /
1.415 (700) / 1.495 (700) / 2.265 (950)
3.00 (550) / 3.1 (550) / 3.36 (550) / 3.43 (550) /
3.53 (600) / 3.63 (600) / 3.66 (600) / 3.72 (600) /
3.82 (600) / 3.86 (600) / 3.89 (600) / 3.95 (600) /
4.25 (650) / 4.38 (650) / 4.45 (650) / 4.54 (650) /
4.64 (700) / 4.9 (700) / 7.43 (950)
Q
min
[L/min]
[gal./min]
1
0.26
1
0.26
p
min
[bar]
[psi]
3
43
3
43
p
max
[bar]
[psi]
5
72
5
72
* D.C. = Duty cycle
**) Lowest cooling power according to standard IEC 60974-2