MHT260a (Engl.)5-9
When the manual indexing selection 0 (48) or the manual indexing selection 1 (49) is allocated to the control input terminal (control input),
the stop position can be changed by the on/off status of those input.
The setting of basic para. 81 is ignored.
Manual indexing selection 1/Manual indexing selection 0
Manual indexing 1 Manual indexing 0
Stop position
OFF OFF Stops at the shortest station with the preset decel. time.
OFF ON Decelerates and stops when the forward (reverse)
command is off. Does not stop at the station position.
ON OFF Stops at the station number position at the ON edge of the
forward (reverse) command.
ON ON Stops at the shortest station with the preset decel. time.
Note: To stop at the station, origin return action (or equivalent) must have been completed.
The station number specified by D14 to D0 can be changed between binary code and BCD code with system para. 98 setting.
Not all of D14 to D0 need to be allocated to the control input terminal.
For RYS□□□S3-RPS type, the initial values are binary, and 6 bits of D5 to D0 are allocated.
For RYS□□□S3-RSS and RTS types, the initial values are BCD.
5.3.2 Pulse train ratio 1/Pulse train ratio 2
The signal validates a pulse train from the manual pulse generator, etc.
Pulse train ratio 1 / Pulse train ratio 2 (Control input signal)
■ Function
While the pulse train ratio 1 (27) is turned on, the pulse train input is valid.
Turning it off ignores the pulse train input.
Pulse train ratio 1 validates the pulse train ratio 1 by basic para. 93, or pulse train ratio 2 validates the pulse train ratio 2 by basic para. 94.
While the pulse train ratio 1 or pulse train ratio 2 is on, and the pulse train input is valid, the manual feed (forward/reverse command
[FWD]/[REV]), origin return [ORG], and auto start [START] do not become valid.
The temporary stop and positioning cancel signals are invalid to the pulse train input is on.
■ Parameter setting
To allocate the pulse train ratio 1 to the control input terminal, set (27) to the system para.. Set (28) for the pulse train ratio 2. If these signals
are not allocated to the control input terminals, these signals are deemed "always off".
K80791234
K80791234K80791234
K80791234
L1
L1L1
L1
L2
L2L2
L2
L3
L3L3
L3
DB
DBDB
DB
P1
P1P1
P1
N
NN
N
P+
P+P+
P+
U
UU
U
V
VV
V
W
WW
W
CHARGE
CHARGECHARGE
CHARGE
FALDIC
FALDICFALDIC
FALDIC
SHIFT
SHIFTSHIFT
SHIFT
ENT
ENTENT
ENT
RYS201S3-VVS
RYS201S3-VVSRYS201S3-VVS
RYS201S3-VVS
MODE
MODEMODE
MODE
ESC
ESCESC
ESC
K80791234
K80791234K80791234
K80791234
L1
L1L1
L1
L2
L2L2
L2
L3
L3L3
L3
DB
DBDB
DB
P1
P1P1
P1
N
NN
N
P+
P+P+
P+
U
UU
U
V
VV
V
W
WW
W
CHARGE
CHARGECHARGE
CHARGE
FALDIC
FALDICFALDIC
FALDIC
SHIFT
SHIFTSHIFT
SHIFT
ENT
ENTENT
ENT
RYS201S3-LPS
RYS201S3-LPSRYS201S3-LPS
RYS201S3-LPS
MODE
MODEMODE
MODE
ESC
ESCESC
ESC
APS30
APS30APS30
APS30
PWR
PWRPWR
PWR
ALM
ALMALM
ALM
SX
SXSX
SX
SCPU32
SCPU32SCPU32
SCPU32
LOADER
LOADERLOADER
LOADER
RUN
RUNRUN
RUN
TERM
TERMTERM
TERM
SLV
SLVSLV
SLV
STOP
STOPSTOP
STOP
CPU
CPUCPU
CPU
No.
No.No.
No.
ONL
ONLONL
ONL
ERR
ERRERR
ERR
RUN
RUNRUN
RUN
ALM
ALMALM
ALM
BAT
BATBAT
BAT
ONL01234567
ONL01234567ONL01234567
ONL01234567
ERR89101112131415
ERR89101112131415ERR89101112131415
ERR89101112131415
ONLCH1
ONLCH1ONLCH1
ONLCH1
ERRCH2
ERRCH2ERRCH2
ERRCH2
EMG+OT‑OT
EMG+OT‑OTEMG+OT‑OT
EMG+OT‑OT
20
2020
20
1
11
1
B/A
B/AB/A
B/A
HP2
HP2HP2
HP2
ONL
ONLONL
ONL
ERR
ERRERR
ERR
PE1
PE1PE1
PE1
PH
PHPH
PH
PL
PLPL
PL
DA
DADA
DA
CH
CHCH
CH
No.
No.No.
No.
SCPU32
SCPU32SCPU32
SCPU32
LOADER
LOADERLOADER
LOADER
RUN
RUNRUN
RUN
TERM
TERMTERM
TERM
SLV
SLVSLV
SLV
STOP
STOPSTOP
STOP
CPU
CPUCPU
CPU
No.
No.No.
No.
ONL
ONLONL
ONL
ERR
ERRERR
ERR
RUN
RUNRUN
RUN
ALM
ALMALM
ALM
BAT
BATBAT
BAT
ONL01234567
ONL01234567ONL01234567
ONL01234567
ERR89101112131415
ERR89101112131415ERR89101112131415
ERR89101112131415
Pulse train input
Pulse train ratio 1 (27)
Pulse train ratio 2 (28)