EasyManua.ls Logo

Fuji Electric Faldic-a RYS-R Series - Compliance with EC Directives; Peripheral Equipment; Power Supply; Power Filter

Fuji Electric Faldic-a RYS-R Series
291 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-7
MHT260a (Engl.)
Compliance with EC directives
• This product should be installed in the electrical cabinet.
• Servo driver is used under the "pollution degree 2" environment as specified in IEC664.
(3) Peripheral equipment
(a) Power supply
The amplifier is used under the "over voltage category II" environment as specified in IEC 664.
The power input unit uses a reinforced isolation transformer based on IEC/EN standards.
A 3-phase, star-connected transformer should be used without regard to single-phase and 3-phase models. The transformer should be
grounded at the neutral point. The phase (line to earth) voltage must not exceed 120 [V].
(2)
(1)
(3)
For the interface power source, use a 24 [V] DC power source with reinforced isolation type input and output.
(b) Power filter
Regarding the EMI terminal disturbance voltage, a power filter is required.
Input voltage class [V] 100 200
Amplifier output [kW] 0.05 to 0.2 0.03 to 0.4 0.75 to 1 1.5 2 3 4 5
Power filter type HF□□□□A-TM 3005 3010 3015 3020 3030 3040 3050
Current [A] 5 10 15 20 30 40 50
Voltage 250[V] AC
Leakage current 1.5 [mA] max. at 250 [V] AC, 60 [Hz]
(5)
(6)
(7) (8)
(9)
(1)
(3)
(2)
(4)
(1) Amplifier
(2) Reinforced isolation transformer
(3) 230 [V] /
3 = 133 [V]
(1) Power supply
source
(2) Amplifier
(3) Motor
(4) Control panel
(5) Reinforced
isolation
transformer
(6) Earth leakage
circuit breaker
(7) Auto circuit
breaker
(8) Power filter
(9) 24 [V] DC power
source

Table of Contents

Related product manuals