EasyManua.ls Logo

Fuji Electric Faldic-a RYS-R Series - Overcurrent, Output Overcurrent; Encoder Trouble; Circuit Trouble, Amplifier Trouble; Data Error, Memory Error

Fuji Electric Faldic-a RYS-R Series
291 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MHT260a (Engl.)9-12
(iii) Data error, memory error
Keypad panel display
!!!
Contents of alarm
Contents of the non-volatile storage memory mounted on the amplifier are destroyed.
Cause, check and remedy
If an alarm appeared immediately after turning on power, contact us.
(iv) Circuit trouble, amplifier trouble
Keypad panel display
!!!
Contents of alarm
The control power supply circuit mounted on the amplifier is abnormal.
Cause, check and remedy
If an alarm appeared immediately after turning on power, contact us.
(v) Encoder trouble
Keypad panel display
!!!
Contents of alarm
The 16-bit serial encoder attached to the motor may be broken.
Cause, check and remedy
If an alarm appeared immediately after turning on power, contact us.
(vi) Overcurrent, output overcurrent
Keypad panel display
!!!
Contents of alarm
The output current from the amplifier to the motor exceeded a specified value.
Cause, check and remedy
The power wiring to the motor may be short-circuited or grounded.
As a general rule, minimum insulation resistance between motor terminals and grounding (earth) terminal (symbol E or ) is about
1 [M"].
The motor winding resistance value between each phase is as same.