MHT260a (Engl.)
7-11
(7) Cumulated pulse
Displays the number of pulse trains inputted to the pulse train input terminal. Inputting the forward pulses increases the integrated value
and inputting the reverse pulses decreases the integrated value.
In case of two 90
° phase-different signals, each edge is counted (quadrupling). The count increases if B phase is in lead.
Remarks : The maximum positive count of 99,999,999 is followed by 0. The maximum negative count of -99,999,999 is followed by 0.
Hence, the count becomes 0 every
± 100,000,000.
4 digits preceded by "H" are high order 4 digits, and those by "L" are low order 4 digits. In case of a negative value, H (or L) and
- (minus sign) blink alternately.
(8) Peak torque
Current load factor of motor. The peak value is displayed every other second in percentage assuming the rated torque as 100%.
The indication is from 0% to maximum torque without minus sign.
(9) Input voltage 1
Indicates the input voltage at the control input terminal [NREF] in 0.1 [V] steps. "-" denotes a negative voltage.
(10) Input voltage 2
Indicates the input voltage at the control input terminal [TREF] in 0.1 [V] steps. "-" denotes a negative voltage.
* Some amplifiers do not have the control input [TREF] terminal.
Pressing the MODE key holding down the SHIFT key
interchanges the high order 4 digits and low order 4
digits.
ENT (1 [s] or more)
ESC
ENT (1 [s] or more)
ESC
ENT (1 [s] or more)
ESC
ENT (1 [s] or more)
ESC