6-44
MHT260a (Engl.)
The following contents of indication can be selected.
Setting Initial indication Setting Initial indication
0 Sequence 7 Feedback speed
1 Sub mode 8 Command speed
2 Alarm detection 9 Actual torque
3 Alarm history 10 Feedback position
4 Amplifier setting 11 Command position
5 Motor setting 12 Deviation amount
6 Station No. indication 13 Cumulated pulse
14 Peak torque
15 Input voltage 1
16 Input voltage 2
17 LS-Z pulse
18 Input signal
19 Output signal
20 Load inertia ratio
(17) System parameter 94, 95Basic type, SX bus, T-link
Para. Name Setting range Initial value Change
94 Parameter rewriting inhibit 0: Rewriting enable
1: Rewriting disable
0Always
Parameter rewriting on the keypad panel can be prohibited.
Even if “1: Rewriting disable” is selected, only the system para. 94 is rewritable.
Remark : Rewrite operation can be restricted by the control input terminal. See 5.6.2 Edit permit command.
(18) System parameter 96Basic type, SX bus, T-link
(a) Basic type
Para. Name Setting range Initial value Change
96 Station number 1 to 31 (in 1 step) 1 Power
(b) SX bus
Para. Name Setting range Initial value Change
96 Station number 0 to 238 (in 1 step) 0 Power