6-43
MHT260a (Engl.)
The assignable signals are as follows:
1 : Run command [RUN] The run command becomes always valid.
14 : ACC0 Only acceleration time 2 and deceleration time 2 become always valid.
27 : Pulse train ratio 1
28 : Pulse train ratio 2
Pulse train ratio 1 or 2 become always valid. Do not assign these two signals 1 and 2 at the same
time.
29 : P-action P-action is always valid. Assignment is not necessary.
30 : Torque limit Torque limit value becomes always valid. Unless assigned, maximum torque limit value (basic para.
59) setting is valid.
43 : Override valid Override becomes always valid.
44 to 47 : Overeride 1, 2, 4, 8 Only specifically determined magnification becomes valid.
48 : Interrupt input valid Interrupt input becomes always valid.
51 to 53 : [X1], [X2], [X3] Only specifically determined multistep speed becomes valid.
Remarks: The signals that have been assigned to system para. 87 or 88 are always valid.
The only two signals can be always valid.
(16) System parameter 89! Basic type, SX bus, T-link"
(a) Basic type
Para. Name Setting range Initial value Change
89 Initial indication 0 to 20 (in 1 step) 0 Power
(b) SX bus, T-link
Para. Name Setting range Initial value Change
89 Initial indication 0 to 20 (in 1 step) 6 Power
The contents of indication on the keypad panel at power on can be changed.