EasyManua.ls Logo

Fuji Electric Faldic-a RYS-R Series - Output Signal; Load Inertia Ratio

Fuji Electric Faldic-a RYS-R Series
291 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MHT260a (Engl.)
7-13
(13) Output signal
Displays whether the control output signals from the amplifier are turned on or off. If signals are turned on, corresponding LEDs are lit.
Note : Depending on the amplifier type, the number of control output signals changes.
(14) Load inertia ratio
Displays the load inertia ratio recognized by the amplifier regardless of the tuning method (basic para. 31).
(Load inertia ratio)
Displays the magnification (in 0.1 step) of the moment of inertia of the motor.
Pressing the MODE key holding down the
SHIFT key interchanges the H side and L side.
ENT (1 [s] or more)
ESC
[OUT24]・・・・・・・・・・・・・・・[OUT18] [OUT17]
[OUT32]・・・・・・・・・・・・・・・・・・[OUT26] [OUT25]
[OUT8]・・・・・・・・・・・[OUT2] [OUT1]
[OUT16] ・・・・・・・・・[OUT10] [OUT9]
ENT (1 [s] or more )
EST
(Moment of inertia recognized by amplifier)
(Moment of inertia of motor)

Table of Contents