7-12
MHT260a (Engl.)
(11) LS-Z pulse
Displays a pulse count from when the origin LS signal has turned off at origin return until when Z-phase of motor encoder has been detected.
The indication is updated at every origin return action. Since the value is in the origin return direction, there is no -(minus sign).
(12) Input signal
Displays whether the control input signals to the amplifier are turned on or off. If signals are turned on, corresponding LEDs are lit.
Note : The number of control input signals depends on the amplifier type.
Pressing the MODE key holding down the SHIFT key
interchanges the high order 4 digits and low order 4
digits.
ENT (1 [s] or more)
ESC
Pressing the MODE key holding down the
SHIFT key interchanges the H side and L side.
ENT (1 [s] or more)
ESC
[CONT24]・・・・・・・・・・・・・・・[CONT18] [CONT17]
[CONT32]・・・・・・・・・・・・・・・・[CONT26] [CONT25]
[CONT8]・・・・・・・・・・[CONT2] [CONT1]
[CONT16] ・・・・・・・[CONT10] [CONT9]