(4) Basic parameter 17 to 20
Para. Name Setting range Initial value Change
17 Override 1 0 to 150% (in 1 step) 10 Always
18 Override 2 0 to 150% (in 1 step) 20 Always
19 Override 4 0 to 150% (in 1 step) 40 Always
20 Override 8 0 to 150% (in 1 step) 80 Always
Override weighting can be changed.
When the override 8, 4, 2 and 1 are all on, adding all initial values gives 150 (= 80 + 40 + 20 + 10). If the initial value has been changed and
resultant sum exceeded 150, the preceding value is retained.
Moving speed [%] by override
Override
8
Override
4
Override
2
Override
1
Moving
speed [%]
OFF OFF OFF OFF 0
OFF OFF OFF ON 10
OFF OFF ON OFF 20
OFF OFF ON ON 30
OFF ON OFF OFF 40
OFF ON OFF ON 50
OFFONONOFF60
OFFONONON70
ON OFF OFF OFF 80
ON OFF OFF ON 90
ON OFF ON OFF 100
ON OFF ON ON 110
ON ON OFF OFF 120
ON ON OFF ON 130
ON ON ON OFF 140
ON ON ON ON 150
* Where override weighting is at initial value.
The override is valid for all of the rotational speed except for the interrupt input and later at interrupt positioning and pulse train ratio 1, 2.