8-4
MHT260a (Engl.)
If a control input signal on CN1 turns on, the corresponding LED lights.
The input signal display [ ] in the monitor mode is updated in real-time.
(2) Manual operation
By turning on the CONT1 [RUN] of amplifier (as factory set), the motor can be rotated.
If output signals (PLC, etc.) to the amplifier are not inputted to the amplifier, check the +24 [V] DC power supply to CN1.
(a) Supply power to the amplifier.
(b) Make sure a voltage is outputted from the +24 [V] DC power supply.
(c) Check the connection of forced stop signal (Beware of NC contact input.)
(d) Turn on the run command [RUN] signal.
By the keypad panel of amplifier, make sure the LEDs light according to the run command.
(e) On the keypad panel, the sequence mode recognized by the amplifier can be checked.
Key operation Indication (example) Remark
Example of monitor mode display
MODE
MODEMODE
MODE
ESC
ESCESC
ESC
The MODE key selects a mode.
MODE
MODEMODE
MODE
ESC
ESCESC
ESC
Change the mode.
MODE
MODEMODE
MODE
ESC
ESCESC
ESC
Change the mode.
MODE
MODEMODE
MODE
ESC
ESCESC
ESC
Change the mode.
MODE
MODEMODE
MODE
ESC
ESCESC
ESC
Change the mode.
By the key or key, select [ ].
SHIFT
SHIFTSHIFT
SHIFT
ENT
ENTENT
ENT
Holding down the ENT key for at least 1 [s] causes a sequence display.
Turning on [RUN] signal displays [ ].
[CONT8]・・・・・[CONT3][CONT2][CONT1]
(Notassigned)   [REV]  [FWD] [RUN]