EasyManua.ls Logo

Fuji Electric Faldic-a RYS-R Series - Page 51

Fuji Electric Faldic-a RYS-R Series
291 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-19
MHT260a (Engl.)
(f) Gear-head unit for GYC cubic type motor, gear ratio 1/25 (for 101 to 751 types) or 1/15 (for 102 to 202 types)
GYN101 to 202CAG - G25 or G15, 0.1 to 2 [kW]
DR DS
Φ
SHAFT
 
EXTENSION
LL LR
LE
QK
φLB
Φ
□LC
4-M5 DEPTH12
(*1)
Φ
SHAFT
 
EXTENSION
LL LR
LE
QK
φLB
Φ
□LC
4-M6 DEPTH15
(*1)
DT DU
Φ
SHAFT
 
EXTENSION
LL LR
LE
QK
φLB
Φ
□LC
4-M8 DEPTH20
(*1)
LL LR
LE
QK
φLB
□LC
φ
φ
4-M10 DEPTH20
SHAFT EXTENSION
(*1)
Type
GYN
Fig Q QK QR φSTUW(*1) LLLLRLGLEφLA φLB LC Mass
[kg]
101CAG-G25 DR 20 15 - 12
0
-0.011
4 2.5 4 M4x8 103 78 25 - 4 60 50
0
--0.025
52 0.72
201CAG-G25 DS 30 23 - 19
0
-0.013
6 3.5 6 M5x13 136 99 37 - 6 90 70
0
--0.03
78 2.1
401CAG-G25 DS 30 23 - 19
0
-0.013
6 3.5 6 M5x13 136 99 37 - 6 90 70
0
--0.03
78 2.1
751CAG-G25 DT 40 30 - 24
0
-0.013
7 4 8 M6x15 166 117 49 - 8 115 90
0
--0.035
98 3.8
102CAG-G15 DU 55 45 - 32
0
-0.016
8 5 10 219 155 64 - 8 135 110
0
--0.035
120 7.8
152CAG-G15 DU 55 45 - 32
0
-0.016
8 5 10 219 155 64 - 8 135 110
0
--0.035
120 7.8
202CAG-G15 DV 55 45 - 32
0
-0.016
8 5 10 258 181 77 - 20 160 130
0
--0.04
140 12.2
-
-
-
(*1) Screw hole (metric diameter x depth) of shaft extension

Table of Contents