6.3 Running the Getting Started Wizard
Dest Gateway Use the IP address of the gateway (192.168.10.1).
l In addition, to enable communication with the target ETERNUS CS800 by means of the
gateway, you must add a second host route in the Routing Details section on the
source ETERNUS CS800.
In this example, you would specify a second set of routing details for the replication
interface on the source ETERNUS CS800:
Destination Use the IP address of the gateway (192.168.10.1).
Dest Netmask Use 255.255.255.255.
Dest Gateway Use the replication IP address of the source ETERNUS CS800
(192.168.10.100).
Figure 88: Interface Routing: Example 3
Backpanel Locations
The Backpanel Locations section at the bottom of the Network page displays a graphical
representation of the Ethernet ports as they appear on the rear of the system.
The diagram indicates the current bonding configuration and connectivity status for all
Ethernet ports.
l Ports that are bonded together in an interface are shaded the same color.
l A green border indicates a port is connected to a network.
l A red border indicates a port is configured but is not connected to a network.
l Click Update Port View to update the information on the diagram.
ETERNUS CS800 118