5.3 Cabling the ETERNUS CS800 S6 System
Every FC port can be configured for PPT.
Initially all FC ports are configured with the VTL target role. The port role can be
changed on page Configuration > System > FC Initiators & Targets of the Remote
Management Console.
Connecting the iRMC port is possible but typically not necessary. For example the
monitoring of the server hardware is included to the general monitoring provided by
the ETERNUS CS800 itself.
The service port of the CS800 should not be connected to the LAN.
CS800 Labelsheet
Together with each ETERNUS CS800 S6 a label sheet is delivered. The stickers on it are
intended to label the storages modules and their power cables (CE, DE-x, JX40-x) as well
as the internal LAN and FC cables to connect the DX100 to the server of the Scale model.
The cells within the tables below should represent the labels. All components delivered
with the initial order of the system are already labeled in the factory, i.e. the appropriate
positions at the sheet will be empty. The remaining labels are either obsolete (e.g. for a
different model of ETERNUS CS800 S6) or may be needed in the future to label additional
storage modules purchased for system enhancement.
DX100 Modules (SCALE)
CE CE CE CE CE CE
DE-1 DE-1 DE-1 DE-1 DE-1 DE-1
DE-2 DE-2 DE-2 DE-2 DE-2 DE-2
DE-3 DE-3 DE-3 DE-3 DE-3 DE-3
DE-4 DE-4 DE-4 DE-4 DE-4 DE-4
DE-5 DE-5 DE-5 DE-5 DE-5 DE-5
DE-6 DE-6 DE-6 DE-6 DE-6 DE-6
DE-7 DE-7 DE-7 DE-7 DE-7 DE-7
DE-8 DE-8 DE-8 DE-8 DE-8 DE-8
DE-9 DE-9 DE-9 DE-9 DE-9 DE-9
DE-a DE-a DE-a DE-a DE-a DE-a