EasyManua.ls Logo

Fujitsu ETERNUS DX60 S3 - Appendix F Basic Size and MWC Input Condition for RAID Groups; Basic Size for each RAID Group; Basic Size When Using the Default Stripe Depth Value (for Standard, TPV, or SDPV Type Volumes)

Fujitsu ETERNUS DX60 S3
1082 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
1054
Appendix F
Basic Size and MWC Input Condition for RAID
Groups
This appendix describes the basic size for each RAID level and the input conditions for the Multi Writeback
Count (MWC) of each RAID group.
F.1 Basic Size for each RAID Group
This section describes the basic size for each RAID level.
The allowed input for the basic size varies depending on the RAID level, the drive configuration, and the Stripe
Depth value.
F.1.1 Basic Size when Using the Default Stripe Depth Value (For Standard, TPV, or
SDPV Type Volumes)
When using the default Stripe Depth value, refer to the following table for basic size:
Basic size of each RAID group when using the default Stripe Depth value
RAID level Drive configuration (*1) Basic size (MB) (Lowest exact MB multiple) (*2)
(Stripe Depth = 64KB (default))
Mirroring (RAID1) 1D+1M 1
High Performance
(RAID1+0)
2D+2M 1
3D+3M 3
4D+4M 1
5D+5M 5
6D+6M 3
7D+7M 7
8D+8M 1
9D+9M 9
10D+10M 5
11D+11M 11
12D+12M 3
13D+13M 13
14D+14M 7
15D+15M 15
16D+16M 1

Table of Contents