Chapter 2 Component Management
2.7 Add Channel Adapter Port
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
242
2.7 Add Channel Adapter Port
This function enables a CA port to be added without stopping the ETERNUS DX100 S3.
For details on the parameters for this function, refer to "A.2.2 Add Channel Adapter Port" (page 780)
.
The procedure to add a CA port is as follows:
1 Click [Add Channel Adapter Port] in [Action].
The [Start] screen appears.
• CA ports can be added for FC, iSCSI, SAS, FCoE, or NAS host interfaces.
• This function cannot be used under the following conditions:
- The general status of the ETERNUS DX100 S3 is not "Normal"
- The minimum port type CA (*1) is not installed in the ETERNUS DX100 S3
*1: CAs with the minimum number of ports that can be installed in the ETERNUS DX60 S3/DX100 S3. 1-port types
and 2-port types are available.
• This function is available only when the ETERNUS DX60 S3/DX100 S3 has a minimum port type CA. Input
the license key for each host interface with the minimum port type, and then add the port.
• The following examples explain how the minimum port type CAs are displayed. Refer to "Channel
Adapter" and "Channel Adapter Detail" in "ETERNUS Web GUI User’s Guide (Operation)" for details.
- For 1-port type
"2port" is displayed as the port type in the [Channel Adapter] screen. However, only one port is
displayed in the [Internal Parts] tab of the [Channel Adapter Detail] screen.
- For 2-port type
"4port" is displayed as the port type in the [Channel Adapter] screen. However, only two ports are
displayed in the [Internal Parts] tab of the [Channel Adapter Detail] screen.