Appendix A Parameter List
A.1 System Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
719
• Authentication Method
• User Name
• Password
● Advanced Settings
• [Change following Timing Parameter items] checkbox
• Connection Timeout
• Response Timeout
• Maximum Retries
Description If "AUTH SMTP" is selected for "SMTP Authentication Information", select the
authentication method.
Input condition/
Display contents
• Automatic
• CRAM-MD5
• PLAIN
• LOGIN
Description When "AUTH SMTP" is selected for "SMTP requires authentication", input the sender user
name.
Input condition/
Display contents
Up to 32 alphanumeric characters and symbols
Description When "AUTH SMTP" is selected for "SMTP requires authentication", input the sender
password.
Input condition/
Display contents
Up to 64 alphanumeric characters and symbols
Description To change the timing parameters, select the checkbox.
Input condition/
Display contents
• Selected
• Cleared
Description Input the timeout limit for SMTP connection.
Input condition/
Display contents
1 - 300 sec.
Description Input the timeout limit for SMTP response.
Input condition/
Display contents
1 - 300 sec.
Description Specify the maximum retry count.
Input condition/
Display contents
0 - 5 count