Device Setting 2
1 Start up the Software Operation Panel.
Refer to Starting Up the Software Operation Panel (page 193).
2 From the list on the left, select [Device Setting 2].
Click an item in the listing on the left to display the details of the settings (parameters) on the right.
The [Default] button resets the settings to the factory default.
The [Save] button saves to a file the values configured in the Software Operation Panel.
The [Restore] button restores from a file the saved values that were configured in the Software Operation
Panel.
Items that can be configured in the above dialog box are as follows:
Item Description Setting/Value Factory Default
Multifeed Specify a method for multifeed
detection. Detect by
monitoring overlapping,
document length, or a
combination of both.
It can also be configured from
the scanner driver's setup
dialog box. Note that priority is
given to the scanner driver
setting.
None / Check Overlapping
(Ultrasonic) / Check Length /
Check Overlapping and Length
Length (when detecting from
the length difference, select
from 10/15/20 mm)
Check Overlapping
(Ultrasonic)
Operational Settings
208