Do you have a question about the GE iVent 201 Series and is the answer not in the manual?
| Type | Ventilator |
|---|---|
| Manufacturer | GE Healthcare |
| FiO2 Range | 21-100% |
| Patient Types | Adult, Pediatric |
| Display | Color touchscreen |
| Model | iVent 201 Series |
Records essential information like model and serial number for service.
Guidance on effectively using the iVentTM201 user's manual.
Identification of the front and back panel components of the iVentTM201.
Crucial safety precautions and warnings for operating the ventilator.
Explanation of standard symbols and labels found on the ventilator.
Details on the performance specifications and ranges of the ventilator.
Physical dimensions and weight specifications for the iVentTM201.
Overview of the different ventilation modes supported by the iVentTM201.
Operating environmental conditions and power supply information.
Specifications for oxygen supply and ventilation performance.
Technical specifications for the optional pulse oximetry function.
Compliance with international standards and safety regulations.
Intended use of the iVentTM201 and guidelines for MRI environments.
Specifications for MRI conditional testing of the iVentTM201.
Overview of the setup process for the iVentTM201 ventilator.
Details on connecting to external AC or DC power sources.
Information on using and managing the internal battery.
Instructions for connecting and using high and low-pressure oxygen sources.
Instructions for connecting disposable, reusable, and dual limb patient circuits.
Checking circuit resistance and details on air inlet, bacterial, CBRN filters.
Connecting HME, MDI, pneumatic nebulizers, and pulse oximeters.
Steps for connecting the ventilator to a heated humidifier.
Connecting remote alarms and maintaining sensor lines.
Connecting the patient and information on filter usage.
Overview of the user interface, front panel, and controls.
Explanation of screen elements, LED indicators, and display information.
Introduction to operating the ventilator and setting modes/parameters.
Steps for powering up, selecting weight, and performing O.V.T.
How to put the ventilator in standby and start patient ventilation.
Step-by-step guide to changing the ventilation mode of the iVentTM201.
Overview and adjustment methods for common ventilation parameters.
Instructions for adjusting the patient's breath rate and tidal volume.
Explanation of breath types and how to adjust pressure settings.
Procedures for adjusting FiO2, peak flow, and pressure support ventilation.
How to adjust PEEP and trigger sensitivity settings.
How to set the duration of the inspiratory phase and rise time.
How to set the flow termination (Esens) for breath delivery.
Introduction to the Main Menu and its functions.
How to navigate through the Main Menu options.
Accessing and adjusting alarm settings.
Accessing and configuring advanced ventilator settings.
How to enable or disable sigh breaths.
Selecting high, low+monitoring, low, or no oxygen supply.
Adjusting the adaptive peak flow setting.
Adjusting humidifier settings.
Accessing and viewing pulse oximetry data and settings.
Configuring nebulizer and setting time and date.
How to restore the ventilator to its factory default settings.
Accessing and viewing ventilation waveforms, graphs, and trends.
How to select which trends to display and browse through data.
Displaying loops and respiratory mechanics measurements.
Configuring pulse oximetry alarms and accessing the log book.
Selecting display modes and performing O.V.T.
Accessing maintenance procedures and information.
Introduction to the Adaptive Bi-Level ventilation mode.
Clinical indications, warnings, and setup for Adaptive Bi-Level.
How to adjust parameters for Adaptive Bi-Level ventilation.
Understanding the display window and Easy Exhale feature.
Optimizing patient interface and resolving breathing dyssynchrony.
Introduction to the alarm system of the iVentTM201.
Explanation of how the ventilator's alarm system functions.
Procedures for responding to and silencing alarms.
How to adjust and configure alarm settings.
How to set respiratory rate, minute volume, pressure, and FiO2 alarms.
How to set the leak alarm and use auto-settings.
Configuring alarm volume, options, and understanding priorities.
Procedures for testing various ventilator alarms.
Troubleshooting sensor failure, patient disconnect, and circuit failed alarms.
Understanding alarm priorities, audible patterns, and definitions.
Introduction to ventilator care, maintenance, and testing procedures.
Procedures for cleaning and maintaining the ventilator.
Schedule and procedures for planned maintenance tasks.
Maintenance procedures for storing the ventilator for extended periods.
Details on the Operational Verification Test (O.V.T).
Navigating and using the Maintenance screen.
Procedures for performing ventilator verification tests.
Adjusting ventilator configuration settings.
Selecting startup screens and changing default patient weight.
Setting the default FiO2 value.
Functions for VersaMed qualified personnel, including communication.
Changing language settings and viewing total operating hours.
Theory behind ventilator components like filters, blending systems, and manifolds.
Theory of turbine unit, pressure sensor, valves, relief valve, and mufflers.
How the ventilator delivers breaths, including phases and control system.
Methods for patient triggering of breaths: pressure, flow, and dual.
Classification of mandatory breaths (ventilator, assist, manual) and patient breaths.
Explanation of Adaptive Flow and Adaptive I-Time features.
How mandatory volume control breaths are delivered.
How pressure control breaths are delivered.
Delivering manual mandatory and patient pressure support breaths.
How spontaneous breaths are delivered.
Summary classification of different breath types.
Detailed explanation of the Assist/Control ventilation mode.
Explanation of the SIMV mode and its breath types.
Explanation of the CPAP mode for spontaneous breathing.
How apnea back-up ventilation is activated and its parameters.
Emergency backup mode for ventilator or sensor failures.
Explanation of the Hold and Clear buttons for measurements.
How to measure static pulmonary mechanics.
Detailed explanation of static compliance measurement.
Step-by-step guide to performing static respiratory mechanics.
Calculation and viewing of the respiratory time constant.
Understanding the RR/VT ratio for breathing assessment.
Information and instructions for disposable breathing circuits.
How to connect and use breathing circuits.
Connecting and using a pneumatic nebulizer.
Details and instructions for reusable patient breathing circuits.
Important warnings and precautions for patient circuits.
Guidelines for sterilizing and using breathing circuits.
Information regarding phthalates in the device.
Steps for connecting and using the humidifier.
Procedures for cleaning and sterilizing breathing circuits.
Steps for disassembling and washing breathing circuit components.
Sterilization parameters and steps for reassembling components.
Information about the dual limb patient circuit adapter.
Instructions for installing the dual limb patient circuit.
Information about the extended battery.
Step-by-step guide to replacing the battery.
Information on the MRI extension tubing set.
Information about the transport mounting plate kit.
How to use the support arm for the breathing circuit.
Connecting the patient circuit to the support arm.
Information about the roll stand accessory.
Steps for mounting and dismounting the iVentTM201 onto the roll stand.
Wiring diagram and pinout for the remote alarm connector.
Part numbers for operation and service manuals.
Part numbers for various breathing circuits and components.
Part numbers for NIV masks.
Part numbers for ventilator filters and adapters.
Part numbers for mounting equipment.
Part numbers for oxygen, SpO2, and remote alarm accessories.
Part numbers for humidifier kits and power cords.
Part numbers for batteries and ventilator cases.
Part numbers for test and calibration equipment.