ADL300 • Functions description and parameters list 71
● If set to 2 the prole used is that shown in the gure below:
PAR 2204
Speed regP2 gain(%)
Gain
PAR 2224
Gain adp spd band3_2 (%)
0
PAR 2208
Speed regP3 gain(%)
Speed ref
PAR 2222
Gain adp spd thr3_2 (%)
Speed ref
PAR 2210
Speed regI3 gain(%)
PAR 2218
Gain adp spd thr2_1 (%)
PAR 2200
Speed regP1 gain(%)
PAR 2202
Speed regI1 gain(%)
PAR 2206
Speed regI2 gain(%)
PAR 2220
Gain adp spd band2_1 (%)
● If set to 3 the prole used is that shown in the gure below:
PAR 2230
Speed reg I0 gain (%)
PAR 2228
Speed reg P0 gain (%)
_
PAR 2248
Gain adp spd band0_2 (%)
_
_
_
Gain
Speed ref
PAR 2202
Speed regI1 gain(%)
PAR 2200
Speed regP1 gain(%)
PAR 2204
Speed regP2 gain(%)
PAR 2206
Speed regI2 gain(%)
PAR 2208
Speed regP3 gain(%)
PAR 2210
Speed regI3 gain(%)
PAR 2222
Gain adp spd thr3_2 (%)
PAR 2220
Gain adp spd band2_1 (%)
PAR 2224
Gain adp spd band3_2 (%)
PAR 2246
Gain adp spd thr0_2 (%)
PAR 2218
Gain adp spd thr2_1 (%)
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
16.16 2232 Spd reg P gain Inuse perc INT16 16/32BIT 100 0 1000 ER F_S
The current proportional coecient of the speed regulator is displayed as a percentage.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
16.17 2234 Spd reg I gain Inuse perc INT16 16/32BIT 100 0 1000 ER F_S
The current integral coecient of the speed regulator is displayed as a percentage.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
16.18 2236 Speed reg P gain N/rpm FLOAT CALCF 0.0 500.0 ERWS F_S
Setting of the proportional coecient of the speed regulator.