PEL-3000(H) User Manual
172
Readjustment is needed when you use a different
operating mode, current range or voltage range.
Cx+CV mode
1. Apply a voltage of 1V to pin J1-1 based on the
level of pin J1-3.
2. Turn VR4 with screwdriver to adjust the value
to 10% of the rating in each +CV mode.
3. Apply a voltage of 10V to pin J1-2 based on the
level of pin J1-3.
4. Turn VR3 with screwdriver to adjust the value
to 100% of the rating in each +CV mode.
5. Apply a voltage of 1V to pin J1-2 based on the
level of pin J1-3.
6. Turn VR4 with screwdriver to adjust the value
to 10% of the rating in each +CV mode.
Readjustment is needed when you use a different
voltage range.