ACO6800+ Installation and Operation Manual 95
Copyright © 2009, Harris Corporation
Chapter 8: ACO6800+ISCST Parameters, LEDs, and Alarms
ACO6800+ISCST Parameters for ASI
Table 8-3. ACO6800+ISCST ASI Parameters
Group Parameter Name
Bank,
Switch
Function Options
General
Serial Number [RO] Displays the serial number of the module <string>
License Key [RO] Displays the license code of the module <string>
Enabled Options
[RO]
Displays the current license option <string>
Factory Recall 0, F Sets your module back to factory default settings
Note There are two independent sets of default
values for SDI mode and ASI mode. Factory Recall in
SDI mode does not affect the parameters in ASI
mode, and vice versa.
Enable
Disable
Soft Reboot 0, E Activates a soft reboot of the module
Enable
Disable
Operation Mode 0, 1 Sets the ACO work mode to SDI or ASI
Note Factory recall does not change this
parameter. It has no default value.
•SDI
•ASI
SubmoduleType
[RO]
Shows whether there is a submodule included on
the module
•None
•For ISCS
Back Module Type Displays the type of back module connected to
the front module
For DS/IDS
•For ISCS
System > Switch Settings
Output Source [RO] Displays the current output source
Input 1
Input 2
Switch High Priority 1, A Sets the high priority for switching
GPI Input
•Manual
•Alarms
Switch Medium
Priority
1, B Sets the medium priority for switching
GPI Input
Manual
•Alarms
Switch Low Priority 1, C Sets the low priority for switching
GPI Input
•Manual
Alarms
Alarms Switch Level 1, D Sets the level for alarm auto switch 1 to 10 (6)
Manual Switch 1, E Sets the what the output source will be when a
channel is switched manually
Disable
•IN_1
•IN_2

Table of Contents