184
13.2 Range Configuration and Accuracy by Clamp-On-Sensor
Power Range Configuration
(when the 9660, 9661, or 9695-03 is used)
Accuracy by Clamp-On Sensor
(when the 9660, 9661, or 9695-03 is used)
13.2 Range Configuration and Accuracy by
Clamp-On-Sensor
Voltage Wiring
Current
9661 CLAMP ON SENSOR
9660/9695-03 CLAMP ON SENSOR (CAT III 300 V)
5.0000 A 10.000 A 50.000 A 100.00 A 500.00 A
150.00 V 1P2W 750.00 W 1.5000 kW 7.5000 kW 15.000 kW 75.000 kW
1P3W
3P3W2M
3P3W3M
1.5000 kW 3.0000 kW 15.000 kW 30.000 kW 150.00 kW
3P4W
3P4W4I
2.2500 kW 4.5000 kW 22.500 kW 45.000 kW 225.00 kW
300.00 V 1P2W 1.5000 kW 3.0000 kW 15.000 kW 30.000 kW 150.00 kW
1P3W
3P3W2M
3P3W3M
3.0000 kW 6.0000 kW 30.000 kW 60.000 kW 300.00 kW
3P4W
3P4W4I
4.5000 kW 9.0000 kW 45.000 kW 90.000 kW 450.00 kW
600.00 V 1P2W 3.0000 kW 6.0000 kW 30.000 kW 60.000 kW 300.00 kW
1P3W
3P3W2M
3P3W3M
6.0000 kW 12.000 kW 60.000 kW 120.00 kW 600.00 kW
3P4W, 3P4W4I 9.0000 kW 18.000 kW 90.000 kW 180.00 kW 900.00 kW
• The range-configuration table shows the full-scale display
value of each measurement range.
• Voltage and current measurements are indicated as 0.4% to
130% f.s. of the range. If a measurement is below 0.4% f.s., it
will be zero-suppressed.
• Power measurement is indicated as 0% to 130% f.s. of the range.
It will be zero-suppressed when the voltage or current is 0.
• The accuracy-guarantee ranges of the 9660/9695-03 and 9661
sensors are 5 A to 100 A and 5 A to 500 A, respectively.
• The range configuration for apparent power (
S
) and reactive
power (
Q
) is the same, except that the unit is changed to VA
and var, respectively.
• When the VT ratio and CT ratio are set, the ranges will be mul-
tiplied by (VT ratio x CT ratio) (when a range falls below 1.0000
mW or exceeds 9.9999 GW, a scaling error occurs and the set-
ting is not accepted).
Range 9660 CLAMP ON SENSOR
9695-03 CLAMP ON SENSOR
9661 CLAMP ON SENSOR
500.00 A
±
0.5%rdg.
±
0.11%f.s.
100.00 A
±
0.5%rdg.
±
0.12%f.s.
±
0.5%rdg.
±
0.15%f.s.
50.000 A
±
0.5%rdg.
±
0.14%f.s.
±
0.5%rdg.
±
0.2%f.s.
10.000 A
±
0.5%rdg.
±
0.3%f.s.
±
0.5%rdg.
±
0.6%f.s.
5.0000 A
±
0.5%rdg.
±
0.5%f.s.
±
0.5%rdg.
±
1.1%f.s.