Redundancy
150
8.3
Redundant coupling
RM Web L3P
Release
4.1
03/08
Two-Switch coupling
Connect the two partners via their ring ports.
Select the Redundancy:Ring/Network Coupling dialog.
Select two-Switch main coupling (see fig. 52).
Figure 52: Two-Switch coupling
The following settings apply to the Switch displayed in blue in the selected
graphic.
Select the coupling port (see fig. 53), (see table 31).
With “Coupling port” you specify at which port you are connecting the
network segments.
If the STANDBY DIP switch is OFF, connect the main line to the cou-
pling port.
Note: Configure the coupling port and the HIPER-Ring ports on different
ports.
Switch Coupling port
RS2-../.. Not possible
RS2-16M Adjustable for all ports (default setting: port 1)
RS20 Adjustable for all ports (default setting: port 1.4)
RS30 Adjustable for all ports (default setting: port 1.4)
RS40 Adjustable for all ports (default setting: port 1.4)
MICE Adjustable for all ports (default setting: port 1.4)
PowerMICE Adjustable for all ports (default setting: port 1.4)
MS 20 Adjustable for all ports (default setting: port 1.4)
MS 30 Adjustable for all ports (default setting: port 2.4)
RSR20/30 Adjustable for all ports (default setting: port 1.4)
MACH 1000 Adjustable for all ports (default setting: port 1.4)
MACH 3000 Adjustable for all ports
MACH 4000 Adjustable for all ports (default setting: port 1.4)
Table 31: Port assignment for the redundant coupling