Redundancy
RM Web L3P
Release
4.1
03/08
8.3
Redundant coupling
153
“Port state”: The port is either connected or not connected.
“IP Address”: The IP address of the partner, if the partner is already
operating in the network.
The displays in the “Information” frame mean (see fig. 53):
“Redundancy guaranteed”: One of the lines affected can fail, as a
redundant line will then take over the function of the failed line.
“Configuration failure”: The function is incomplete or incorrectly
configured.
To avoid continuous loops, the Switch sets the port state of the coupling
port to “off” if you:
switch off operation or
change the configuration
while the connections are in operation at these ports.
Note: The following settings are required for the coupling ports (you
select the Basic Settings:Port Configuration dialog):
Port: on
Automatic configuration (autonegotiation):
on for twisted-pair connections
Manual configuration: 100 Mbit/s FDX
for glass fiber connections
Note: If VLANS are configured, note the VLAN configuration of the
coupling and partner coupling ports.
In the Network/Ring Coupling configuration, select for the coupling and
partner coupling ports
VLAN ID 1 and “Ingress Filtering” disabled in the port table and
VLAN membership U in the static VLAN table.
Note: Operating the redundancy manager and two-Switch coupling func-
tions at the same time runs the risk of creating a loop.