EasyManua.ls Logo

Hirschmann Power MICE - Page 161

Hirschmann Power MICE
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Redundancy
RM Web L3P
Release
4.1
03/08
8.3
Redundant coupling
161
To avoid continuous loops, the Switch sets the port state of the coupling
port to “off” if you:
switch off operation or
change the configuration
while the connections are in operation at these ports.
Note: The following settings are required for the coupling ports (you
select the Basic Settings:Port Configuration dialog):
Port: on
Automatic configuration (autonegotiation):
on for twisted-pair connections
Manual configuration: 100 Mbit/s FDX
for glass fiber connections
Note: If VLANS are configured, note the VLAN configuration of the
coupling and partner coupling ports.
In the Network/Ring Coupling configuration, select for the coupling and
partner coupling ports
VLAN ID 1 and “Ingress Filtering” disabled in the port table and
VLAN membership U in the static VLAN table.

Table of Contents

Other manuals for Hirschmann Power MICE

Related product manuals