8. MAINTENANCE OPERATIONS
8-11
8.3 Startup Suppression on Serious Failure Detection
This equipment suppresses startup of the equipment when one of the following incidents is
detected during Windows® startup in order to protect the hardware.
1. Fan failure
2. Remote shutdown signal input
< NOTE >
In the case of a remote shutdown signal input, startup is suppressed only when
Enable automatic shutdown at remote shutdown input is selected in the RAS
setting window. If an automatic shutdown is not selected, startup is not suppressed.
For information about how to use the RAS setting window, refer to HF-W7500
Model 65/60 RAS FEATURES MANUAL (WN-63-0101). When a remote shutdown
signal input is detected, the equipment displays a blue screen and then stops.
For information about the STOP error code of this case, see 9.3 STOP Error
Codes.