9. TROUBLE SHOOTING
9-23
Table 9-3 lists event log entries unique to the equipment. No.1 through 19 and No.22 through
31 are collected in the system log, and No.20 and 21 are collected in the application log.
Table 9-3 Event Log Entries Unique to the Equipment (1/3)
No.
Event
ID
Source
Type
Description
Action
1
17
WHEA-Logger
Warning
A fixed hardware error has
occurred.
No handling.
* This log may be recorded when an
expansion board equipped with a PCI
Bridge IC is mounted in slot 4 of the
expansion slot.
2
257
HFWRAS_SYS
Error
Revolutions of fan at
power supply deteriorated
remarkably.
Read the description of fan failure in
9.2.2 (1)” and take an action
accordingly.
3
259
HFWRAS_SYS
Warning
The temperature
exceeded prescribed value.
Read the description of abnormal
temperature in “9.2.2 (1)” and take action
accordingly.
4
260
HFWRAS_SYS
Information
Remote shutdown request
occurred.
No handling.
5
261
HFWRAS_SYS
Information
Revolutions of fan at
power supply returned to
normal value.
No handling.
6
263
HFWRAS_SYS
Information
Temperature returned to
prescribed value.
No handling.
7
265
HFWRAS_SYS
Warning
A failure may be imminent
on the drive of the drive
bay%1 (%2).
We recommend you back up the data and
replace the drive.
8
268
HFWRAS_SYS
Error
The computer was shut
down because temperature
became dangerous.
Read the description of abnormal
temperature in “9.2.2 (1)” and take action
accordingly.
9
270
HFWRAS_SYS
Information
Used hours on the drive of
the drive bay%1 exceeded
prescribed value.
We recommend you back up the data and
replace the drive.
10
279
HFWRAS_SYS
Error
Revolutions of system fan1
deteriorated remarkably.
Read the description of fan failure in
9.2.2 (1)” and take an action
accordingly.
11
280
HFWRAS_SYS
Information
Revolutions of system fan1
returned to normal value.
No handling.
12
281
HFWRAS_SYS
Error
Revolutions of system fan2
deteriorated remarkably.
Read the description of fan failure in
9.2.2 (1)” and take an action
accordingly.