9. TROUBLE SHOOTING
9-23
Table 9-3 lists event log entries unique to the equipment. No.1 through 19 and No.22 through
31 are collected in the system log, and No.20 and 21 are collected in the application log.
Table 9-3 Event Log Entries Unique to the Equipment (1/3)
A fixed hardware error has
occurred.
No handling.
* This log may be recorded when an
expansion board equipped with a PCI
Bridge IC is mounted in slot 4 of the
expansion slot.
Revolutions of fan at
power supply deteriorated
remarkably.
Read the description of fan failure in
“9.2.2 (1)” and take an action
accordingly.
The temperature
exceeded prescribed value.
Read the description of abnormal
temperature in “9.2.2 (1)” and take action
accordingly.
Remote shutdown request
occurred.
Revolutions of fan at
power supply returned to
normal value.
Temperature returned to
prescribed value.
A failure may be imminent
on the drive of the drive
bay%1 (%2).
We recommend you back up the data and
replace the drive.
The computer was shut
down because temperature
became dangerous.
Read the description of abnormal
temperature in “9.2.2 (1)” and take action
accordingly.
Used hours on the drive of
the drive bay%1 exceeded
prescribed value.
We recommend you back up the data and
replace the drive.
Revolutions of system fan1
deteriorated remarkably.
Read the description of fan failure in
“9.2.2 (1)” and take an action
accordingly.
Revolutions of system fan1
returned to normal value.
Revolutions of system fan2
deteriorated remarkably.
Read the description of fan failure in
“9.2.2 (1)” and take an action
accordingly.