81
Confirm that the ink stream bending or nozzle clogging has been corrected.
For the check procedure, see to in "5.4.1. Nozzle Backwash".
[If makeup stream is not in the center of the gutter]
● If the stream deviates significantly from the gutter, the nozzle orifice may not have been cleaned
sufficiently. Perform the procedure described in "5.4.2. Disassembly and Cleaning of Nozzle Orifice"
again. If the problem is not corrected even after it is performed, contact your nearest local distributor.
● If the stream is in the gutter but deviates from the center of the gutter, adjust the stream position
according to "5.5. Stream Alignment".