4.1. Wiring Precautions 
 
(1)  Wiring 
 
● If extraneous noise enters the unit, it may malfunction or fail. 
To improve noise immunity, observe the following wiring precautions. 
 
 
Electric signal connection diagram 
 
①  Keep the power cable to the unit away from other power supply cables (in particular, a speed control inverter 
power supply cable, etc.). Putting them into different ducts provides better performance. 
②  Wire input/output (I/O) signal cables individually. Do not bundle them together with other power supply 
cables. 
③  Electrically isolate the print target detector, print head, stand, and main body from other machines (such as a 
conveyor). 
④  Keep the wiring of print target detector away from other power supply cables. 
⑤  Ensure that all electrical wiring, connections, and grounding comply with applicable cords. If a malfunction 
occurs due to noise, make a separate ground connection.