124
6.2. Cautions on Installation of Cleaning Station
(1) Keep the areas shown in the figure below around the Cleaning Station for daily operations, handling,
maintenance, and inspection.
Installation position of Cleaning Station
(2) Install the Cleaning Station and cleaning cable under the conditions below.
Failure to observe them may affect cleaning performance (cleaning ink stains or drying the head).
Install the Cleaning Station within 1.5 m above and 1.0 m below the installation surface of the main body.
Make sure that the length of raising the cable from the Cleaning Station is 0.5 m.
Install the Cleaning Station horizontally.
Install the Cleaning Station cable at a bend radius of 150 mm or longer.
Installation positions of Cleaning Station and cleaning umbilical cable
Maintenance area
(side)
400 mm
110 mm
Top
Bottom
Maintenance area
(front)
300 mm
Back
Front
300 mm
750 mm
IJP main body
(Cleaning station
mounting part)
0.5 m
1.5 m
Cleaning station
Cleaning umbilical cable
IJP main body
1.0 m
Cleaning station
including the cable
Installation surface
of the main body