6.4. Maintenance of Cleaning Station
6.4.1. Cleaning station filter
If the end of the print head is entirely wet after head cleaning, the cleaning station filter may be clogged.
In that case, replace the cleaning station filter.
6.4.2. Cleaning solvent container
As a guide, replace the cleaning solvent container two years after use. If its surface is broken, cracked, or
chipped before a lapse of two years, it should be replaced.
After it is left for a long time, the float may be stuck.
Replace the cleaning solvent container if the float is still stuck even after cleaning it with makeup.
Print head
End of the head
Cleaning station
Cleaning station filter
Liquid may accumulate due to clogging of the
filter part or the liquid leakage hole (not
shown).
Float
Cleaning
solvent
container
The float is used to detect the liquid level in
the cleaning solvent container.