6.3.5. Automatic Circulation during Stop (S)
Prevent sticking by using the Cleaning station to automatically operate the unit periodically.
6.3.5.1. Operation of Automatic Circulation during Stop (S)
This section describes the operation of automatic circulation during stop (S).
NOTE
If the unit is powered off when automatic circulation during stop (S) is in progress, the process
is aborted.
In the case power it on, and perform automatic circulation during stop (S) again.
Automatic circulation during stop (S) will use approximately 8 ml of Makeup per day. If some
faults occur when automatic circulation during stop (S) is in progress, this process
automatically restart only once after cleaning print head. (Approximately 40 ml makeup will be
consumed). If the warning [Makeup Low Warning] appear when automatic circulation during
stop (S) is in progress, the process is aborted. Please check the Makeup level and replenish as
needed before starting this process.
If a fault is detected when automatic circulation during stop (S) is in progress, the process is
aborted.
Insert the print head into the Cleaning station.
(See Steps to in "11.2. Head Cleaning Using Cleaning station"" of the Instruction Manual.)
Press Automatic Circulation during Stop(S) on the [Safe clean station function] screen.