6. Safe-Clean Station (Optional parts)
6.1. Installation of Cleaning Station
This section describes how to install the Cleaning Station.
CAUTION
If the Cleaning Station is installed at a place higher than your eye level (such as a high place),
makeup may splash on your face due to incorrect operation of the unit. Build scaffolding to
keep the unit at a place lower than your eye level, or install a cover to prevent makeup from
splashing on your face.
NOTE
Solvent steam is produced in the Cleaning Station during drying. When working around the
unit, sufficiently provide ventilation with a ventilating facility. Install the ventilation facility under
the unit because it efficiently discharges solvent steam heavier than air.
If it is required to install the Cleaning Station away from the main body, install it within the range
where the print head cable can be inserted with allowance. Otherwise, an unexpected
malfunction such as a break in the cable may occur.
6.1.1. How to Install Cleaning Station on Main body
This section describes how to install the Cleaning Station on the main body.
(1) Remove the handle on the left when viewing the main body from the front. You can remove the M4
screws at 2 locations shown below to remove the handle.
Handle
M4 screw (at 2 locations)