34
(b) Output signal (IJ Printer -> external unit)
Electrical characteristics of output signals (IJ Printer -> external unit)
No.
Signal name
Function
Electrical characteristics
1
Ready
Operates when the IJ Printer is
in the ready state.
No-contact output
Open collector (NPN)
Sink current: Maximum
20 mA
ON voltage: 0.5 V or less
Operating voltage: 30 V or
less
Relay output (optional)
Contact C x 1 (*5)
30 VDC/1A,
30 VAC/0.5 A
(resistance load) (*6)
2
Fault
Operates when the IJ Printer is
in the fault state.
3
Warning
Operates when the IJ Printer is
in the warning state.
4
Print-in-progress
(*7)
Operates when printing is in
progress in the IJ Printer.
No-contact output
Open collector (NPN)
Sink current: Maximum
20 mA
ON voltage: 0.5 V or less
OFF: Open
Operating voltage: 30 V or
less
No-contact output
Open collector (PNP)
Source current: Maximum
10 mA
(Connect a resistance load of
2.2 kΩ or more.)
ON voltage: +24 V output
OFF: Open
Print-complete
(*7)
Operates when the IJ Printer
completes printing.
(pulse output of up to one
second)
5
Online output
Operates when the IJ Printer is
online.
(*5): For inductive load, protect the contact with a surge absorber and others.
(*6): Relay output and no-contact output can be used at the same time.
(*7): Select either [print.-in-progress] or [print. complete] on the screen.