57 
4.3.4.5. Warning Signal Output (Output via NPN Interface: Pin Number 13 on Terminal Block 
TB1, Relay Output: Pin Numbers 7 to 9 on Terminal Block TB5 *TB5 IS OPTIONAL 
PARTS.) 
The warning signal output provides a function that outputs a signal to the outside indicating that the IJ Printer 
is in warning mode. 
 
[When the signal is connected to relay output] 
 
(1)  When NO (contact a) is used 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
(2)  When NC (contact b) is used 
 
 
 
 
 
 
 
 
 
 
 
 
 
For warning and fault output, each of NO and NC contacts supports a capacity of up to 100 VAC/0.5 A or 
30 VDC/1 A. For the use of the unit under a load larger than the capacity, interpose another relay in the 
connection. 
When the load is an inductive load such as a motor or a relay, counter electromotive force may be 
generated, which may shorten the life of the contact. Be sure to protect the contact according to the wiring 
of ready output signal.