72
(c) Put the inner cover back to its original position. (See “5.2. Removing Inner Cover".)
(d) Remove the print head cover and put the end of the print head in the beaker to be ready for ink
ejection.
(e) Press OK. After refilled, the ink is ejected from the nozzle inside the print head.
The ink is ejected from the nozzle after a while. Check the ink stream position.
To abort the ink ejection, press Abort and follow the displayed operation guidance. After the
completion of the abort process, you are returned to the [Circulation control] screen. When the
abort process has been performed, select [Ink refill] on the [Circulation control] screen.