GX-Series Control Panel Installation and Setup Guide
B-5
Ev SIA Event Log Log Event Ev Type Contact
Description Event Description Trigger ID
Event
K - Heat (Custom SIA - See Note 2)
KA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
KB Bypass OMITTED zone omitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
KJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
KR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
18.ZN RESTO
KT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
KU Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
L - Phone, Program
LB Program begin ENGINEER+ Engineer mode entered MISC ALWAYS TR 627
TEST O/P USER NONE 0
FULL TEST SET NONE 0
MOD T/D USER NONE 0
MOD CODES USER NONE 0
MOD REM USER NONE 0
OMIT ZONE USER NONE 0
ENG PARAM USER NONE 0
ENG ZONES USER NONE 0
ENG O/PS USER NONE 0
ENG LINKS USER NONE 0
ENG SOAK USER NONE 0
ENG DIGI USER NONE 0
ENG PRINT USER NONE 0
ENG QUICK USER NONE 0
ENG DIAG USER NONE 0
ENG GROUP USER NONE 0
ENG ASSEM USER NONE 0
ENG TMRS USER NONE 0
ENG CHECK USER NONE 0
LR Line Restore LINE FAIL- Zone Tel line fail rest. ZONE 12.MD/COM 351
LINE FAIL- Module Tel line fail rest. MOD 12.MD/COM 351
LT Line Trouble LINE FAIL+ Zone Tel line fail trouble ZONE 12.MD/COM 351
LINE FAIL+ Mod Tel line fail trouble MOD 12.MD/COM 351
LX Local Prog end ENGINEER- Engineer mode exited EVENT ALWAYS TR 627
M - Medical (Custom SIA - See note 2)
MA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
MB Bypass OMITTED zone omitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
MJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
MR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
18.ZN RESTO
MT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
MU Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
O - Opening
OA Open Report UNSET Automatic Unset EVENT 10.SETTING 401
OG Open Area UNSET Part Unset USER 10.SETTING 401
KSW UNSET Keyswitch part unset ZONE 10.SETTING 409
OK Early Open U/S EARLY Unset Early EVENT 10.SETTING 451
OP Open Report UNSET Unset USER 10.SETTING 401
KSW UNSET Keyswitch unset ZONE 10.SETTING 409
OR Disarm alarm SYS RESET All Burglar alarms reset USER 11.RESET 313
PA RESET All PA alarms reset USER 1.PA/DURE 465
TAMP RST All Tamper alarms reset USER 9.TAMPER 313
SYS RESET Ksw reset Burglar alarm EVENT 11.RESET 313
PA RESET Ksw reset PA alarms EVENT 1.PA/DURE 465
TAMP RESET Ksw reset Tamp alarm EVENT 9.TAMPER 313
LF RESET USER 20.FAULT 313